Before you start
- Check the Collector can reach the DIDO on TCP 6970.
- To recall presets from the portal, save them on the DIDO first (in its web interface). Their names appear in the Presets reading.
Add the device
- In the portal, go to Devices and select New device.
- Choose the Collector that can reach the device, and set Protocol to Aurora DIDO.
- Enter the settings below and save. The Collector picks up the new device within seconds.
Readings
These values appear under Device Information on the device page, and can be checked in Room Readiness routines.Commands
Each command is a button on the device page, and can be used in Room Readiness routines.Readings: the input shown on each output (Out1 Source to Out4 Source), each output’s resolution, the audio routing, line-out and line-in volume, whether the front panel is locked, and the saved presets.
Commands: Route Out1 to Route Out4 switch one output to an input; Route All switches every output. Set Volume sets the line-out level. Recall Preset applies a saved preset; it takes the DIDO two or three seconds.
New firmware: if a reading shows as … Reply with the device’s raw answer instead of a value, the firmware answers in a form the Collector doesn’t recognise yet. Send the reply to support so it can be added.
Updated 26 Oct 2026 11:57 · page 03655b8