Works with: Crestron 3-Series and 4-Series control processors, such as the CP4, MC4, RMC4, CP3 and PRO3.

Before you start

  1. Note a processor user that can log in to its console (the same login Crestron Toolbox uses). 4-Series processors require authentication; turn it on for a 3-Series that doesn’t have it.
  2. Check the Collector can reach the processor on TCP 22. If SSH is turned off on the processor, add the tag console: ctp and allow TCP 41795 instead.
  3. On a 4-Series running its program in a slot other than 1, add the tag program_slot with that slot number.

Add the device

  1. In the portal, go to Devices and select New device.
  2. Choose the Collector that can reach the device, and set Protocol to Crestron control processors.
  3. Enter the settings below and save. The Collector picks up the new device within seconds.

Readings

These values appear under Device Information on the device page, and can be checked in Room Readiness routines.

Commands

Each command is a button on the device page, and can be used in Room Readiness routines.
No change to the room’s program. The Collector reads what the processor’s own console reports. Nothing is loaded onto the processor.
Connected devices: every device the program registers by IP ID (touch panels, DM and NVX endpoints, expanders) is listed with its status, as readings such as Ipid 03 Status. Ip Devices Offline counts those that are offline, and Offline Ip Devices names them, so a check or alert can catch a panel that has dropped off.
Commands interrupt the room. Restart Program restarts the program in its slot, and Reboot restarts the processor. The room stops working until it’s back, usually within a minute or two.
Unrecognised output: console output differs between firmware versions. If a reading shows as … Reply with the processor’s raw output instead of a value, send it to support so it can be added.