Skip to main content
Reports shows how your estate has been doing over a period: which devices have been down, which rooms are used, which are noisy, which assets are going out of warranty, and how much power the rooms use. Go to Reports in the sidebar. You need the View reports permission. If your access is limited to some locations, buildings or rooms, reports only cover those.

Choose the period

Use Window at the top to choose the period: 24h, 7d, 30d or 90d. Warranty isn’t windowed, because it’s about each asset’s end date, so the picker hides for it.

Export

Select CSV to download the report you’re looking at, for the period you’ve chosen and any room tag you’ve picked, ready to open in a spreadsheet.

Filter by room tag

If your organisation uses room tags, a All room tags menu appears beside Window. Pick a tag to limit every report, and its CSV, to the rooms with that tag.

Device uptime

The share of polls in the period in which each device reported online, with its location, how many polls it had, its current status and when it was last seen. The cards at the top count the devices observed, and how many are at 99% uptime or above, and below it. A device that hasn’t been polled in the period, such as one just added, shows — rather than 0%: it hasn’t been observed, not necessarily down.

Room usage

How much each room is used. A room is in use for any hour in which a video codec reported a call or a camera counted people in it. For each room you see: Displays on is shown separately and isn’t counted as use, because Room Readiness switches displays on every morning whether anyone comes in or not. It leaves out the time Room Readiness runs were working on the room. A room with no device that reports calls or people says No usage data rather than showing as unused.

Device events

How many events each room’s devices raised in the period, split into Alerts, such as devices going offline or reporting faults, and Messages, which devices send unprompted, such as Telnet output or DSP updates. Normal polling isn’t counted. A high count points at a noisy or faulty device, not a busy room. For how much a room is used, see Room usage.

Warranty

Every asset’s warranty end date and the days left, grouped as Expired, within 30, 90 or 365 days, Later, or No date for assets without an end date recorded. Retired assets are left out. Add warranty dates on the Assets page.

Power

An estimate of each room’s energy use in kWh for the period, worked out from its devices’ power ratings and uptime, and the kWh saved by the Room Readiness overnight power-down. Only devices with a power rating count. Devices without one are counted as Unrated, so you can see where ratings are missing. Add them in Power on (watts) and Power standby (watts) when you edit a device.

How up to date reports are

Device uptime, Room usage and Power are worked out from daily summaries of each device’s readings:
  • Periods are whole days, in UTC.
  • They can be up to about 20 minutes behind the newest readings.
  • They cover up to a year of history. Raw readings are kept for 90 days, and daily summaries for 400 days.

Updated 06 Nov 2026 14:07 · page 83f2584