Skip to main content
Works with: Biamp Tesira DSPs, including TesiraFORTÉ, over the Tesira Text Protocol (TTP).

Before you start

  1. Make sure Telnet is enabled on the Tesira, which is the default.
  2. If the Tesira has login security turned on, note a username and password to enter on the device.
  3. In Tesira software, find the instance tags of the blocks you want to control or read, such as a level block or a meter.

Add the device

  1. In the portal, go to Devices and select New device.
  2. Choose the Collector that can reach the device, and set Protocol to Biamp Tesira.
  3. Enter the settings below and save. The Collector picks up the new device within seconds.

Readings

Every Tesira reports its identity and health on each poll: hostname, part number, serial number, software version, IP and MAC address, fault count and the active fault list. Readings from your own DSP blocks are added per device in the Readings section of the device form:
  • Add readings for a DSP block takes the block type, its instance tag, and a channel range such as 1-8:
    • Meter: one snapshot reading per channel, in dB.
    • Level: each channel’s level (dB) and mute, updated live.
    • Mute: each channel’s mute, updated live.
    • Logic meter: each channel’s logic state, updated live.
    • VoIP call state: the phone’s call state, updated live, plus an _active_calls reading that counts calls in progress.
  • Snapshot reads a value on every poll, which suits meters. Live updates the moment a value changes and records each change as an event, which suits mute or call state.
  • Mutes and logic states read as true or false, and levels and meters as numbers, so Room Readiness routines can check them, for example that a microphone isn’t muted. The all-channel attributes levels and mutes read as a list of every channel.

Commands

Tesira commands are TTP strings you define per device in the Commands section of the device form. Each command becomes a button on the device page.
  • Add commands for a DSP block takes the block type and its instance tag:
    • Level: mute, unmute, toggle mute, volume up and down by the step you choose, and set level.
    • Mute: mute, unmute and toggle mute.
    • Logic state: on, off and toggle.
    • Source selector: select source, which asks for the source number (0 selects none).
    • VoIP phone: dial (asks for the number), answer and hang up, on the line you choose.
    Use channel 0 for a ganged block. Press each new command once from the device page to check it against your design.
  • Once the device is saved and its Collector has connected, the Instance tag boxes suggest the blocks in the DSP’s design. The Collector reads them each time it connects, so a newly loaded design appears after its next reconnect.
  • Add preset recall adds DEVICE recallPreset {preset}.
  • Put {name} in a command to ask for a value when the button is pressed, for example master_level set level 1 {level}.
The TTP form is <instance tag> <verb> <attribute> <channel> [value], for example master_level set mute 1 true.

Updated 23 Oct 2026 15:20 · page 97bad9e