> ## Documentation Index
> Fetch the complete documentation index at: https://docs.marcus.involvecloud.com/llms.txt
> Use this file to discover all available pages before exploring further.

# Aurora RXT-x Touch Panels

> Wall-mount control touch panels. JSON-RPC over Telnet on port 6975, with proximity, lux, and relay control.

**Works with:** Aurora Multimedia RXT-x wall-mount touch panels.

| | |
| - | - |
| **Type** | Vendor adapter |
| **Vendor** | Aurora Multimedia |
| **Device types** | Control |
| **Connection** | JSON-RPC over Telnet (TCP 6975) |
| **Power on/off from the portal** | No |
| **Protocol in the portal** | Aurora RXT-x Touch Panels (`aurora_rxt`) |

## Before you start

1. Check the Collector can reach the panel on TCP 6975.
2. If the panel is secured, note its login username and password.

## Add the device

1. In the portal, go to **Devices** and select **New device**.
2. Choose the **Collector** that can reach the device, and set **Protocol** to **Aurora RXT-x Touch Panels**.
3. Enter the settings below and save. The Collector picks up the new device within seconds.

| Setting | Required | What to enter | Example |
| - | - | - | - |
| **Address** | Yes | Panel IP or hostname (port 6975 is implied). | `192.168.1.50` |
| **Username** | No | Login username if the panel is secured. | `admin` |
| **Password** | No | Login password if the panel is secured. | |

## Readings

These values appear under **Device Information** on the device page, and can be checked in Room Readiness routines.

| Reading | Shown as |
| - | - |
| `volume` | Volume |
| `mute` | Mute |
| `lcd_brightness` | Lcd Brightness |
| `lcd_timeout` | Lcd Timeout |
| `lux` | Lux |
| `proximity` | Proximity |
| `auto_brightness` | Auto Brightness |
| `relay_N` | Relay N |
| `event_manager` | Event Manager |
| `response_ms` | Response Ms |

## Commands

Each command is a button on the device page, and can be used in Room Readiness routines.

| Command | Button | Notes |
| - | - | - |
| `reboot` | Reboot | |
| `factory_default` | Factory Default | |
| `test_audio` | Test Audio | |
| `mute` | Mute | |
| `unmute` | Unmute | |
| `auto_brightness_on` | Auto Brightness On | |
| `auto_brightness_off` | Auto Brightness Off | |
| `relay_1_on` | Relay 1 On | |
| `relay_1_off` | Relay 1 Off | |
| `relay_1_toggle` | Relay 1 Toggle | |
| `relay_2_on` | Relay 2 On | |
| `relay_2_off` | Relay 2 Off | |
| `relay_2_toggle` | Relay 2 Toggle | |

> [!NOTE]
>
> **Touch-panel web UI:** **Touch Panel** on the device page opens the panel's own page (`/user`, or the device's `touch_panel_path` tag) through remote access, so it works from anywhere. It needs the **Remote access** permission.

Updated 06 Nov 2026 14:07 · page e80a127


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.